LAUNDRY BOILER - Oil/Gas
(40 - 350 kg/h)

KSA SERIES - Made in Saudi Arabia

Steam generation capacity: 40 kg/h - 350 kg/h

Operating Pressure: 1-8 Bar

Fuel Type: Natural Gas, LPG, Diesel

Boiler System Accessories
  • Two pass, reverse flame type steam boiler
  • Baltur Burner
  • 1 operating brand feed water pump group with valves, filters and check valves
  • Electrical control panel
  • Ari Armature brand safety valve
  • High quality electronic water level control systems
  • Manometer and 3-way connection valve
  • Reflex glass water level indicator
  • Pressure switch
  • acuum breaker and shut-off valve
  • Flue temperature sensor
  • High quality steam exit valve, water inlet valve and check valve
  • Bottom blowdown valve and bottom blowdown shut-off valve
  • Economizer, Water Softener, Thermic Deaerator, Automatic Bottom and Surface Blowdown Systems, PRV station, Steam Header, Steam trap, 3 way valve (Optional)
Engineering Design
Technical Table
KSA SERIES LAUNDRY STEAM BOILERS KSA40 KSA80 KSA120 KSA180 KSA250 KSA350
Steam Generation Capacity (kg/h) 40 80 120 180 250 350
Max. Working Pressure (bar g) 4 4 4 5 6 6
Total Heat Transfer Surface Area (m2) 1.8 3.5 5.6 7.7 10.4 15
Thermal Capacity (kW) 25 50 75 113 157 220
Fuel Consumption/Diesel (kg/h) 2.6 5.2 7.8 11.7 16.5 23.2
Power(KW) 0.9 1.15 1.15 1.7 1.7 1.7
Connection Voltage 220V/1PH 220V/1PH 220V/1PH 220V/1PH 220V/1PH 220V/380V/3PH
Length (L) (mm) 1000 1250 1500 1750 2000 2250
Width (W) (mm) 750 900 950 1050 1150 1250
Height (H) (mm) 950 1100 1150 1250 1350 1450
Weight (kg)* 486 750 985 1248 1510 1742
KSA SERIES غسيل ملابسالمراجل البخارية KSA40 KSA80 KSA120 KSA180 KSA250 KSA350
(kg/h) قدرة توليد البخار ٤٠ ٨٠ ١٢٠ ١٨٠ ٢٥٠ ٣٥٠
(bar g) ضغط العمل الأقصى ٤ ٤ ٤ ٥ ٦ ٦
(m2) إجمالي مساحة سطح نقل الحرارة .٨ ١
Gallery